Disk Read and Write Speed Test
Section: Server Operations / Windows Server Operations Applies to: Windows Server 2008 R2 or later, Windows 7 or later (32/64-bit) Tool: Parkdale 3.08 (free, portable, no installation required)
1. Overview
When a server runs slow queries, lags during video playback, or takes a long time to boot, the cause is often insufficient disk throughput rather than the application itself. CPU and memory exhaustion raise alarms, but a slow disk is usually silent — every indicator looks normal while the amount of data actually written to disk per second is far below what is needed.
A single Parkdale benchmark gives you the real read and write capability of the machine, which helps you determine:
- Whether the disk meets its rated performance (HDD, SATA SSD, NVMe, cloud volumes, and RAID arrays differ enormously)
- Whether the disk is aging, has bad sectors, or has lost its cache advantage
- Whether a cloud volume is being rate-limited (same specification from different vendors can differ by 3–5×)
- Whether replacing disks, expanding capacity, or moving to a RAID array actually brought improvement
2. Getting the Software
Parkdale is developed by the sz development (Germany) and is distributed free of charge from the official website. It is portable — extract and run, no installation.
Official download (the only trustworthy source)
- Product page: https://www.the-sz.com/products/parkdale/
- Windows direct link: https://www.the-sz.com/common/get.php?product=parkdale
Attachment: Parkdale-3.08-official.zip is attached to this article. It was downloaded unchanged from the official site above; extract it and run Parkdale.exe directly.
Verification data (check the package yourself to confirm it is genuine)
| Item | Value |
|---|---|
| Filename | Parkdale.zip |
| Version | 3.08 |
| Size | 849 KB (869,129 bytes) |
| SHA256 | 20ad93d321dd30672d482603b9a3eaa1e1b1317ee5cefaaa15f439fe320da45b |
| Company | the sz development |
| Copyright | Copyright © 2001-2025 |
⚠️ Important: Many third-party "disk tool" download sites repackage Parkdale and may bundle adware or ship a modified executable. Obtain it only from the-sz.com or from the attachment on this page.
To verify, open PowerShell on Windows and run
Get-FileHash Parkdale.zip -Algorithm SHA256. If the result matches the value above, the package is the official release.You can also install it through a package manager, which pulls from the official source:
winget install --id the-sz.Parkdale -e

3. Operating Instructions
Place Parkdale.exe in any directory on the server (for example D:\tools\), double-click to run, then follow three steps:
Select the target disk in the left-hand list
Leave
File Sizeat the default value of1000MBClick Start and wait for the benchmark to finish (about 10–60 seconds depending on disk speed)
Four results are reported: sequential write speed, 4 KB random write, sequential read speed, and 4 KB random read.
Note: The test writes a 1000 MB temporary file to the target volume and deletes it automatically when finished. Before testing the system volume, make sure at least 2 GB is free. On production servers, avoid running the benchmark during peak hours.
4. Reference Results
The following measurements were taken on different storage media and can serve as a baseline for judging whether a given machine's disk performance is normal.
4.1 Cloud Server SSD (Aliyun)
KVM virtualization platform, disk presented as a Red Hat VirtIO paravirtual device.

| Metric | Result |
|---|---|
| Sequential write | 106.1 MB/s |
| Sequential read | 106.3 MB/s |
| 4 KB random write | 7.9 MB/s, 2009.7 IOPS, 0.50 ms |
| 4 KB random read | 7.8 MB/s, 2002.5 IOPS, 0.50 ms |
Cloud volume sequential speed is capped by the bandwidth quota of the instance, so it is not comparable to a local SSD running at 500 MB/s or more. These figures are normal for an entry-level cloud disk and do not indicate a fault.
4.2 Notebook SSD (Apple MacBook, BootCamp)

| Metric | Result |
|---|---|
| Sequential write | 609.4 MB/s |
| Sequential read | 474.2 MB/s |
| 4 KB random write | 19.7 MB/s, 5051.2 IOPS, 0.20 ms |
| 4 KB random read | 18.5 MB/s, 4745.9 IOPS, 0.21 ms |
Typical NVMe SSD performance. With over 5000 IOPS and 0.2 ms random access latency, this class of drive handles database workloads very well.
4.3 Server SSD Array (Dell PERC H730P)

| Metric | Result |
|---|---|
| Sequential write | 2028.4 MB/s |
| Sequential read | 606.4 MB/s |
| 4 KB random write | 42.7 MB/s, 10925.0 IOPS, 0.09 ms |
| 4 KB random read | 42.5 MB/s, 10885.7 IOPS, 0.09 ms |
An SSD array behind a RAID controller with write cache. Sequential write exceeds 2000 MB/s (the write cache is doing its job), IOPS are above 10,000, and latency is 0.09 ms — the ideal state for a database server.
4.4 Ordinary HDD (HGST HTS721010A9E630)

| Metric | Result |
|---|---|
| Sequential write | 65.2 MB/s |
| Sequential read | 110.1 MB/s |
| 4 KB random write | 554.7 KB/s, 138.7 IOPS, 7.21 ms |
| 4 KB random read | 1020.7 KB/s, 255.2 IOPS, 3.92 ms |
A typical 5400/7200 RPM 2.5-inch hard drive. Random access latency of 3–7 ms is 20–40× that of an SSD — which is exactly why "the database is on a spinning disk and it is slow". Sequential throughput is adequate, but small-file and index lookups suffer badly.
4.5 Server SAS HDD (Dell R710, SEAGATE ST3600057SS)

| Metric | Result |
|---|---|
| Sequential write | 102.6 MB/s |
| Sequential read | 188.0 MB/s |
| 4 KB random write | 1102.6 KB/s, 275.6 IOPS, 3.63 ms |
| 4 KB random read | 1264.3 KB/s, 316.1 IOPS, 3.16 ms |
A 15,000 RPM SAS drive. Both sequential and random performance clearly beat ordinary SATA HDDs, but it is still bound by mechanical seek time, so random latency remains above 3 ms.
5. Reading the Results
| Metric | Meaning | Notes |
|---|---|---|
| Seq. Write Speed | Sequential write | Relevant for large file copies and video recording |
| Seq. Read Speed | Sequential read | Relevant for large file reads and video playback |
| Random QD32 | 4 KB random at queue depth 32 | Relevant for databases, VMs and small files |
| IOPS | I/O operations per second | Higher is better; SSD 5000+, HDD 100–300 |
| ms | Average access latency | Lower is better; SSD 0.1–0.3 ms, HDD 3–10 ms |
How to judge
- Sequential speed far below the rated value → check the interface (SATA II caps at 300 MB/s), cables, RAID mode, or cloud volume bandwidth quota
- Abnormally low random IOPS (HDD below 80) → possible bad sectors or severe fragmentation
- Results fluctuating more than 30% across repeated runs on the same disk → disk health is questionable; check SMART data
- Cloud server consistently below comparable machines → check for rate limiting or heavy host load
6. The Three Test Modes
Parkdale has three tabs at the top. QuickAccess is sufficient for daily use:
| Mode | How it works | When to use |
|---|---|---|
| QuickAccess | Tests through the filesystem: sequential read/write plus 4 KB random with 32 threads; multiple drives can be tested in sequence with results written to a log | Routine checks and multi-drive comparison (recommended) |
| FileAccess | Reads and writes an ordinary file through the filesystem | When you need to simulate real file I/O |
| BlockAccess | Bypasses the filesystem and reads/writes disk sectors directly, with a transfer-rate graph | Diagnosing bad sectors and observing speed degradation over time |
A command-line build, ParkdaleCmd.exe, is available for unattended batch testing:
ParkdaleCmd.exe -d D:\ -s 1000 -b 1024 -l 1
Parameters: -d target drive, -s test file size in MB, -b block size in KB, -l write a log file (1 = yes, 0 = no).
7. Notes
- The test actually writes 1000 MB of data, which slightly consumes SSD endurance; there is no need to run it frequently (once a quarter, or when replacing a disk, is enough)
- Do not run a large test on a system volume with little free space — filling the volume will cause system problems
- Write cache on a RAID controller is only enabled when a BBU or supercapacitor is present; that is when 2000 MB/s-class write results appear
- Results inside a virtual machine are affected by host load and can vary noticeably between runs on the same VM
- These numbers measure performance only, not disk health; if you suspect a failing disk, combine them with SMART data (
smartctl -a, CrystalDiskInfo)